Cerlic ITX TSS sensor for MLSS

  • A high accuracy, online, NIR (near infrared) total suspended solids (TSS) sensor for MLSS (mixed liquor suspended solids)
  • Built-in self-cleaning (NOT clipped on) with water or compressed air - no moving parts for low maintenance
  • NO service agreements
  • Range: 0 » up to 20,000mg/L (ppm) or 2% TSS - dependent on sludge
  • Process connection: handrail or slide rail mount
  • Temperature: 0 » 60°C
  • Enclosure: IP68 (submersible)
  • Life expectancy: sensor 10yrs 
  • Accuracy: ±0.5% FS (TSS)
  • Outputs: 4»20mA or optional Profibus DP from BB1 (single sensor - link) or BB2 (up to 4 sensors - link) controller
  • Wetted Materials: 316SS & BK7 glass
  • See the self-cleaning in action - YouTube demo
  • See the telescopic rod with rail mounting kit in action - YouTube demo
Back to top
 

Cerlic ITX-IL in-line TSS sensor for RAS / WAS / DAF thickened sludge

  • A high accuracy in-line NIR (near infrared) total suspended solids (TSS) sensor for RAS (return activated sludge) / WAS (waste activated sludge) & some DAF (dissolved air floatation) thickened sludge
  • Built-in self-cleaning (NOT clipped on) with water or compressed air - no moving parts for low maintenance
  • NO service agreements
  • Range: 0 » up to 50,000mg/L (ppm) or 5% TSS - dependent on sludge
  • Process connection: hot-tap via isolation valve prevents having to stop process in case of maintenance
  • Temperature: 0 » 60°C
  • Enclosure: IP65
  • Life expectancy: sensor 10yrs 
  • Accuracy: ±1% FS (TSS)
  • Outputs: 4»20mA or optional Profibus DP from BB1 (single sensor - link) or BB2 (up to 4 sensors - link) controller
  • Wetted Materials: 316SS & BK7 glass 
Back to top
 

Cerlic CMC high concentration TS sensor

  • Micowave, high concentraion total solids (TS) sensor
  • True phase-shift microwave technology provides stable signal & prevents empty pipe errors
  • No moving parts for long life & low maintenance
    • Angled sensor (antenae) surfaces for self-cleaning
  • Designed for digested, dewatered or primary sluge
  • Range: up to 30% TS (300,000mg/L or ppm)
  • Process connection: wafer flange for DN50 » 300, insertion type model also
  • Conductivity: varies depending on pipe size - refer datasheet
  • Process pH: 2.5» 11.5
  • Temperature: 0 » 100°C
  • Pressure: PN16 (recommend at least 1.5bar to remove air from sludge / biosolids)
  • Supply: 85»264Vac
  • Display: remote mount with supplied 10m cable
  • Enclosure: IP65
  • Accuracy: ±1% FS (TSS)
  • Outputs: 2 x 4-20mA or HART analogue outputs - TS concentration & sludge temperature
Back to top
 

Cerlic Solido TSS sensor for RAS / WAS / MLSS

  • A high accuracy NIR (near infrared) total suspended solids (TSS) sensor for RAS (return activated sludge) / WAS (waste activated sludge) / MLSS (mixed liquor suspended solids)
  • Plug and play connection to the MultiTracker handheld controller
  • Range: 0 » up to 50,000mg/L (ppm) or 5% TSS - dependent on sludge
  • Depth: up to 12m
  • Temperature: 0 » 50°C
  • Enclosure: IP68 (handheld MultiTracker IP65)
  • Accuracy: ±1% FS (TSS)
  • Output: graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (high & low)
  • Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
  • Wetted Materials: 316SS, BK7 glass & PUR (cable)
  • NEW! With the latest Firmware update of the MultiTracker (v2.3) the Solido can now store & use three separate calibration curves
    • Operators can now datalog for three separate applications (e.g. MLSS, RAS & effluent) with the one device, without having to re-calibrate for each between uses!
    • Head to the MultiTracker page (here) to download the updates
Back to top
 

Cerlic O2X DUO dissolved oxygen sensor (optical or galvanic)

  • Built-in self-cleaning (NOT mounted externally) with water or compressed air - no moving parts for low maintenance
    • NO service agreements
  • Range: 0 » 20mg/L
  • Outputs: 4»20mA or optional Profibus DP from BB1 (single sensor - link) or BB2 (up to 4 sensors - link) controller
  • Mounting: submersible sensor (IP68) mounted on 4m spring loaded telescopic rod (fibreglass), slide rail or chain
  • Life expectency:
    • Consumable sensing cells: 18»24 months (electrochemical), 2»3yrs luminophore (factory replacement) & 5»10yrs cell (complete optical cell)
    • Sensor: 10yrs
  • Temperature: 0»50°C
  • Wetted materials: 316SS
  • See the telescopic rod with rail mounting kit in action - YouTube demo
  • See the self-cleaning in action - YouTube demo
Back to top
 

Cerlic OxyDuo dissolved oxygen (DO) sensor

  • Dissolved oxygen (DO) sensor with your choice of optical or electrochemical (Clarke) cell
    • Swappable at any time
  • Plug and play connection to the MultiTracker handheld controller
  • Only ever replace the consummable sensing cell
  • Range: 0 » up to 20mg/L (ppm)
  • Depth: up to 12m
  • Temperature: 0 » 50°C
  • Enclosure: IP68 (handheld MultiTracker IP65)
  • Accuracy: Electrochemical: ±1% FS, Optical: ±0.1mg/L <5mg/L, ±0.2mg/L > 5mg/L
  • Output: graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (high & low)
  • Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
  • Wetted Materials: sensor cell components, 316SS body & PUR (cable)
Back to top
 

TriOS OPUS hyperspectral process sensor

  • Measurement technology:attenuation
    • Wavelength: full spectrum from 200 » 360nm (hyperspectral)
    • Resolution: 0.8nm/pixel
    • Compensation: turbidity
  • Pathlength: customised - 0.3 » 50mm
  • Used for measuring: nitrate (NO3), nitrite (NO2), COD eq (chemical oxygen demand equivalent), BOD eq (biological oxygen demand), DOC eq (dissolved organic carbons), TOC eq (total organic compound), TSS eq (total suspended solids), KHP (potassium acid pthalate), SAC 254 (organic matter), COD-SAC eq & BOD-SAC eq
  • Self-cleaning: compressed air & unique hydrophobic nano-coating of lenses
  • Wetted materials: stainless steel (316Ti / 316L) or titanium (sea water applications)
  • Supply: 12 » 24Vdc (±10%)
  • Interface: digital - ethernet, RS-232, RS-485 (Modbus RTU)
    • Datalogger: yes, 2GB internal
  • Temperature: 2 » 40°C
  • Pressure: 30bar (SubConn connection), 3bar (fixed cable) or 1bar (in flowcell)
  • Ingress protection: IP68
Back to top
 

TriOS LISA UV optical SAC254 (or UVT) sensor

  • The new (previously LISA-254) low-cost state-of-the-art SAC254 instrument from TriOS optical sensors.
    • Application dependent calibration for COD, BOD, TOC or UVT can be done, offering online measurement of this parameters at a fraction of investment and service costs of other SAC254 probes or classical cabinet analysers. 
  • LISA can be customized with optical path lengths of 1, 2, 5, 10 or 50 mm to cover almost every application. The use of a second wavelength offers automatical internal turbidity correction of the SAC value.
  • Innovative long lifetime UV-LED technology and a robust design are the key-features of LISA.
    • Like every TriOS sensor, LISA has nano coated windows to avoid fouling. Combined with airblast cleaning service costs are reduced to a minimum.
  • The unique TriOS G2 interface allows easy and fast 3rd party integration to existing SCADA systems or dataloggers, beside the use within the wide range of TriOS controllers and handheld devices.
    • Additional to the digital outputs, LISA is available with direct 4..20 mA interface.
  • The titanium version of LISA allows the use in very harsh environments (e.g. high chlorine concentrations). 
Back to top
 

TriOS NICO low cost optical nitrate meter

  • TriOS has now developed NICO: a UV photometer for the determination of nitrate.
  • The four detection channels enable a precise optical determination of nitrate by absorption, taking into account turbidity and organic substances that pose a problem for many products currently on the market.
  • An internal temperature correction additionally increases stability of the measured values.
  • Equipped with our innovative G2 interface with web browser configuration, internal data logger, flexible protocols and data outputs, NICO boasts features that are much more advanced than comparable devices higher available on the market at a very advantageous price. a standardized spare parts and consumables system.
    • The cutting-edge G2 interface not only enables quick integration into third-party systems, but also use of the wide range of accessories for our devices. 
Back to top
 

TriOS VIPER optical hyperspectral sensor

  • VIPER measures hyperspectral attenuation and transmission coefficients in the wavelength range of 360nm » 750nm, enabling detailed determination of multiple parameters at the same time.
    • The light source is provided by 5 selected, energy-saving LEDs that guarantee a long service life and stable measurement data.
  • VIPER can be used in different media as it is available in multiple path lengths, both in stainless steel or titanium housing.
  • Typical applications for VIPER are water quality monitoring, colour measurements of aqueous solutions or quality monitoring of drinking water.
    • Additional parameters can be installed by means of software if necessary at a later time.
  • Like all TriOS sensors, VIPER is equipped with a nano-coated optical window that protects against fouling. 
  • Equipped with our innovative G2 interface with web browser configuration, internal data logger, flexible protocols and data outputs, VIPER boasts features that are much more advanced than comparable devices higher available on the market at a very advantageous price. a standardized spare parts and consumables system.
    • The cutting-edge G2 interface not only enables quick integration into third-party systems, but also use of the wide range of accessories for our devices
Back to top
 

TriOS LISA colour optical colourimetry sensor

  • LISA color is the new low-cost colour probe in the TriOS family.
  • The key features of the probe are longevity with innovative LED technology, the rugged and smart housing for maximum flexibility of use as well as the novel and intuitive user interfa 
  • The unique TriOS G2 interface allows easy and fast 3rd party integration to existing SCADA systems or dataloggers, beside the use within the wide range of TriOS controllers and handheld devices.
    • Additional to the digital outputs, LISA is available with direct 4..20 mA interface.
Back to top
 

TriOS enviroFlu optical oil in water (PAH) meter

  • Operating principle: fluorescence
  • Used for: PAH (polycyclic aromatic hydrocarbons) detection in water
    • Typical applications are discharge monitoring of airports and factories, leakage detection and many others.
  • enviroFlu is a new generation of high sensitive submersible sensors for oil-in-water measurement. The used UV fluorescence principle for detection is much more sensitive than any other existing detection principle, like infrared scattering, etc. This allows the detection of PAH traces in water down to single ppb levels (e.g. in drinking water or condensate applications).
  • The sensors can be used either in stationary or portable applications.
  • A new innovative nano-coating on the lenses is preventing the optics from fouling and oil-films, making the enviroFlu-HC longterm stable and virtually maintenance free.
  • In addition, the enviroFlu-HC can be used with an compressed air cleaning system. For a chemical-free check on location solid standards, so called SolidCAL's, are available.
  • On request special application requirements can be met by changing the filter combinations, possible for example is an enviroFlu-BT for determination of BTX in water.
  • The enviroFlu-BT is also available in a deepsea version for operation in water depth down to 6,000 m (enviroFlu DS).
Back to top
 

TriOS nanoFlu low cost, miniature, optical, fluorometer

  • the nanoFlu is a low-priced, submersible and miniature fluorescence sensor for highly precise & selective measurement of CDOM (coloured dissolved organic matter, yellow substances), rhodamine, chlorophyll A in green algae or phycocyanin in cyanobacteria.
  • Operating principle: fluoresence
  • Measuring range: 0 - 200µg/L
  • Accurancy: ± 3 %
  • Media:
    • Temperature: 2 - 40°C
    • Pressure: 3bar (fixed cable) or 30bar (SubConn connector)
    • Inflow velocity: 0.1 - 10 m/sec
    • Ingress: IP68 
  • Long-term stability of measurements is ensured by the combination of low power consumption & innovative coating of the optical window, as an energy efficient and environmentally friendly antifouling solution.
  • The submersible nanoFlu can be used in diverse range of applications including the realtime monitoring of:
    • sea, river or freshwater reservoir systems
    • incoming / outgoing flow at drinking & wastewater treatment plants
    • potential filter membrane leaks during rhodamine testing
  • Internal reference signals of the high performance LEDs used for fluorescence excitation compensate ageing effects and temperature influences.
  • G2 interface
Back to top
 

TriOS matrixFlu UV optical fluorescence measurement sensor

  • Our high-end matrixFlu fluorometer combines multiple excitation and detection wavelengths for fluorescence measurements in a single device that boasts a highly compact design. MatrixFlu boasts extensive features that go significantly beyond what's available on the market today.
    • The special optical arrangement of excitation and detection channels enables not only single values to be determined, but also a 3x4 or 4x4 matrix of wavelength combinations, depending on type.
    • This allows quasi synchronous in-situ detection of EEMs (Emission Excitation Matrices).
  • matrixFlu is primarily designed for the detection of PAH's (polycyclic hydrocarbons), FDOM (fluorescent organic material), and tryptophan (aromatic amino acid).
  • State-of-the-art, specially selected LEDs are used for fluorescence excitation.
  • The stability of measured values is boosted by an internal temperature correction.
  • Equipped with our innovative G2 interface with web browser configuration, internal data logger, flexible protocols and data outputs,
    • The state-of-the-art G2 interface not only ensures quick integration into third-party systems, but also use of the wide range of accessories for our devices.
Back to top
 

TriOS surFlu optical oil film on water detection sensor

  • Oil spills and related oil pollution pose a potential risk for businesses that use oils or lubricants in their processes in any way. Alongside our world-leading enviroFlu (refer separate listing) for the detection of very small amounts in water, we now offer surFlu for the detection of oil films on water.
  • State-of-the-art, stable UV LED technology for fluorescence excitation and multiple detection channels for reliable detection of smallest oil films on water enable universal application of the device. Multi-channel detection ensures reliable differentiation from biogenic films (which are caused e.g. by dead algae), foliage, humic substances, undulations, thus avoiding false alarms.
  • The special geometry of the optics allows large variance in the distance between sensor and water surface, so that even highly fluctuating water levels in basins, gullies, streams or rivers will have no impact on the measuring signal. The stability of measured values is boosted by an internal temperature correction.
  • Equipped with our innovative G2 interface with web browser configuration, internal data logger, flexible protocols and data outputs, surFlu boasts extensive features that go significantly beyond what's available on the market today. 
    • The state-of-the-art G2 interface not only ensures quick integration into third-party systems, but also use of the wide range of accessories for our devices. 
Back to top
 

TriOS microFlu CDOM, chlorophyll or cyanobacteria miniature fluorometer

  • Discontinued - see nanoFlu above
  • Used for: CDOM, chlorophyll or cyanobacteria miniature fluorometer
  • microFlu fluorometers are low-cost, miniature and submersible for high precision, selective measurement of CDOM (Coloured Dissolved Organic Matter), chlorophyll-A or cyanobacteria. The combination of low power consumption, innovative nano coating as energy and environmental neutral fouling protection and longterm stability makes it suitable for monitoring in rivers, lakes, seawater and for all applications in the field of water quality and wastewater monitoring.
  • Internal reference measurement of the emitted light compensates aging effects of the high-efficient LEDs, used for fluorescence excitation. 
Back to top
 

TriOS RAMSES spectral imaging radiometer for radiance or irradiance in UV, VIS & UV/VIS

  • RAMSES radiometer are stand-alone and highly integrated hyperspectral radiometer for the UV, VIS and/or UV/VIS spectral range.
    • Small size and very low power consumption make them suitable for hand-held and autonomous applications.
  • The RAMSES radiometer family is especially designed for combining precision hyperspectral light measurement with a maximum of flexibility. The modular measurement system reduces the price and many accessories as well as custom made solutions grant a broad range of applications like installations on ships, handheld usage or autonomous measurements in remote places, like the Arctic or Antarctic.

 

Back to top
 

Cerlic CBX & CBX Plus sludge blanket level (SBL) & profile sensor

  • Combines NIR suspended solids sensor with accurate depth measurement to provide sludge blanket profile
  • Analogue outputs for: sludge blanket level, fluff (unsettled sludge) level, real-time TSS concentration & real-time sensor depth
  • 4-20mA or Profibus DP output (optional)
  • Completely self-cleaning
  • Two models:
    • CBX: range up to 2% TSS (depending on sludge type)
    • **coming soon** CBX Plus: range up to 5% TSS (depending on sludge type)
  • See it in action - YouTube demo
Back to top
 

Cerlic Blanko sludge blanket level (SBL) & profile sensor

  • Combines a NIR (near infrared) suspended solids sensor with hydrostatic pressure transducer to accurately plot TSS vs depth for complete sludge blanket profile
  • Plug and play connection to the MultiTracker handheld controller
  • Range: 0 » up to 20,000mg/L (ppm) or 2% TSS - dependent on sludge
  • Depth: up to 19m
  • Temperature: 0 » 50°C
  • Enclosure: IP68 (handheld MultiTracker IP65)
  • Accuracy: ±1% FS (TSS), ±0.5% FS (depth)
  • Output: profile via graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (fluff & sludge blanket)
  • Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
  • Wetted Materials: 316SS, BK7 glass & PUR (cable)
  • See it in action - YouTube demo
Back to top
 

Cerlic MultiTracker with MultiSeries sensors

  • Handheld controller for MultiSeries plug and play sensors
  • Parameters: sludge blanket profile (Blanko), total suspended solids (Solido) & dissolved oxygen (OxyDuo)
  • Datalogging: 250 samples
  • Display: backlit graphical LCD
  • Alarms: vibration & audio at adjustable set points
  • Keypad: push-button programming of all setttings
  • Supply: 4 x AA (approx. 2»yrs operation, sensor dependent)
  • Cables: 4, 8, 12 or 20m
  • Enclosure: IP65
  • See it in action - YouTube demo
  • NEW! With the latest Firmware update of the MultiTracker (v2.3) the Solido can now store & use three separate calibration curves
    • Operators can now datalog for three separate applications (e.g. MLSS, RAS & effluent) with the one device, without having to re-calibrate for each between uses!
  • Software & drivers
    • TrackerTalk 1.0
    • USB-to-Serial converter (now available for up to Windows 10) - to download:
        • scroll down to Support & Download tab
        • then scroll down to Software & Drivers & under the heading of Windows Software & Driver click the link to download the most suitable (& up to date) .zip version of the driver for your computer
        • extract the .zip file and follow the on-screen prompts to install the driver to your PC
        • NOTE: please do this BEFORE plugged your MultiTracker datakit in for the first time to ensure the correct driver is loaded.  Depending on your computer settings this may require Administrator access
    • Latest Firmware Update (HEX2_3) - please strictly follow the TrackerTalk upgrade directions when updating the Firmware
Back to top
 

Cerlic Blanko sludge blanket level (SBL) & profile sensor

  • Combines a NIR (near infrared) suspended solids sensor with hydrostatic pressure transducer to accurately plot TSS vs depth for complete sludge blanket profile
  • Plug and play connection to the MultiTracker handheld controller
  • Range: 0 » up to 20,000mg/L (ppm) or 2% TSS - dependent on sludge
  • Depth: up to 19m
  • Temperature: 0 » 50°C
  • Enclosure: IP68 (handheld MultiTracker IP65)
  • Accuracy: ±1% FS (TSS), ±0.5% FS (depth)
  • Output: profile via graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (fluff & sludge blanket)
  • Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
  • Wetted Materials: 316SS, BK7 glass & PUR (cable)
  • See it in action - YouTube demo
Back to top
 

Cerlic Solido TSS sensor for RAS / WAS / MLSS

  • A high accuracy NIR (near infrared) total suspended solids (TSS) sensor for RAS (return activated sludge) / WAS (waste activated sludge) / MLSS (mixed liquor suspended solids)
  • Plug and play connection to the MultiTracker handheld controller
  • Range: 0 » up to 50,000mg/L (ppm) or 5% TSS - dependent on sludge
  • Depth: up to 12m
  • Temperature: 0 » 50°C
  • Enclosure: IP68 (handheld MultiTracker IP65)
  • Accuracy: ±1% FS (TSS)
  • Output: graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (high & low)
  • Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
  • Wetted Materials: 316SS, BK7 glass & PUR (cable)
  • NEW! With the latest Firmware update of the MultiTracker (v2.3) the Solido can now store & use three separate calibration curves
    • Operators can now datalog for three separate applications (e.g. MLSS, RAS & effluent) with the one device, without having to re-calibrate for each between uses!
    • Head to the MultiTracker page (here) to download the updates
Back to top
 

Cerlic OxyDuo dissolved oxygen (DO) sensor

  • Dissolved oxygen (DO) sensor with your choice of optical or electrochemical (Clarke) cell
    • Swappable at any time
  • Plug and play connection to the MultiTracker handheld controller
  • Only ever replace the consummable sensing cell
  • Range: 0 » up to 20mg/L (ppm)
  • Depth: up to 12m
  • Temperature: 0 » 50°C
  • Enclosure: IP68 (handheld MultiTracker IP65)
  • Accuracy: Electrochemical: ±1% FS, Optical: ±0.1mg/L <5mg/L, ±0.2mg/L > 5mg/L
  • Output: graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (high & low)
  • Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
  • Wetted Materials: sensor cell components, 316SS body & PUR (cable)
Back to top
 

Cerlic pHx (pH) & ReX (ORP or redox) sensors

Back to top
 

TriOS clear water & immersion turbidity sensor

Back to top
 

AW Proscan turbidity sensor for dairy applications (A3 certified)

  • See more in this short YouTube video
Back to top
 

TriOS ORP / redox digital differential sensor

Back to top
 

TriOS ORP / redox digital sensor

Back to top
 

TriOS pH digital differential sensor

Back to top
 

TriOS pH digital sensor

Back to top
 

TriOS conductivity sensor

Back to top
 

TriOS free chlorine sensor

Back to top
 

TriOS chlorine dioxide sensor

Back to top
 

Cerlic BB2 centralised control box for X-series sensors

  • Controls up to 4 sensors at once, including self-cleaning solenoids
  • Outputs: 2 x 4-20mA as a standard, but expandable up to 4 x 4-20mA for 4 online sensors
    • Use for analytical variables (TSS / DO etc) or temperature
    • Profibus output optional
  • Supply: now available with 24Vdc without having to change sensors!
Back to top
 

Cerlic BB1 central control box for X-series sensors

  • Controls just one sensor
  • Outputs: all outputs from one sensor
    • 2 x 4-20mA as a standard, but expandable up to 4 x 4-20mA for CBX with full range of outputs (sludge blanket level, fluff level, real-time depth & concentration)
      • Use for analytical variables (TSS / DO etc) or temperature
      • Profibus output optional
  • Supply: 85 - 230Vac
Back to top
 

TriOS TriBox3 centralised sensor controller

  • For centralised controll & programming of up to 4 x TriOS sensors
  • Outputs:
    • Modbus, 4-20mA (6 OFF), SPDT relay, ethernet etc
    • Datalogger: yes
    • Sensor self-cleaning: built-in solenoid valve (air)
  • Enclosure:IP65
    • Temp: 0»40°C (ambient)
  • Supply: universal
    • 85»265VAC &
    • 12»24VDC
Back to top
 

TriOS TriBox Mini low cost controller for one sensor

  • Lower cost controller for up to two sensors
  • Outputs:
    • Modbus, 4-20mA (6 OFF), SPDT relay, Wi-Fi
    • Datalogger: yes
  • Supply: universal
    • 85»265VAC &
    • 12»24VDC
  • Requires external solenoid valve for self-cleaning (refer pdf)
Back to top
 

TriOS G2 Interface Box for all G2 sensors

  • G2 interface for local / network configuration and communication with G2 compatible sensors.
  • Supply: 24VDC
  • Outputs: Modbus, ethernet, Wi-Fi & ethernet models available
  • Enclosure: IP20 (NOT weatherproof)
    • Temp: 0»40°C
Back to top
 

TriOS HS100 G2 DIN rail interface for all TriOS G2 sensors

  • G2 interface for local / network configuration and communication with G2 compatible sensors.
  • Supply: 24VDC
  • Outputs: Modbus, ethernet, Wi-Fi
  • Enclosure: IP20 (NOT weatherproof)
    • Temp: 0»40°C
Back to top
 

TriOS sensor mounting clamps

  • Available in multiple sizes, these mounting clamps can be used to mount almost any of the TriOS sensors.
  • NOTE: for best performance always mount sensors at a slight angle to prevent the entrapment of air bubbles on the sensing surface
Back to top
 

TriOS AirShot

  • Self-contained system provides instant pressuried air cleaning for use with all TriOS sensors where compressed air isn't readily available
  • Supply: 100 » 240VAC (max. 4A)
  • Temp: -5 » 35°C
  • Encl: IP44 for venting
  • Weight: ~4kg
  • Cleaning: up to 7 bar
    • Freq: (std) is 15secs every 15mins, (max) up to 6secs every 2mins (@ 20°C)
    • Output: pulsed spray
  • Connections: 3m power cable supplied, 5m comms cable between compressor & TriOS controller (TriBox3 or TriBox Mini), 10m air tube between compressor & valve (cannot be shortened) and 5m air tube between valve & sensor fitting (can be shortened).
Back to top
 

TriOS ultrasonic flowcell

  • Just like a standard flowcell, but fitted with ultrasonic cleaning to reduce maintenance of your TriOS photometers like the OPUS, NICO & LISA!
    • Suitable for all photometers with path lentgh up to 10mm
  • Built-in viewing window allows for quick inspection of the sensor
  • Supply: 12 » 24VDC (±10%). ~15W
  • Temperature: -20 » 70°C (ambient)
  • Pressure: 1 bar (max.)
  • Process connections: tube pushfittings - 8mm (inlet) & 6mm (outlet)
  • Through flowrate: 2 » 4L/min
  • Enclosure: IP64
  • Mat'ls: Polyoxymethylene (POM)
  • Coming soon - flurometer version
Back to top
 

TriOS flowcells

  • Available in different sizes for the various TriOS sensors
  • Pressure: 1 bar (max.)
  • Process connections: tube pushfittings - 8mm (inlet) & 2 x 6mm (outlet)
  • Through flowrate: 2 » 4L/min
Back to top
 

TriOS sensor mounting floats

  • For one or two sensors - NOTE: a specific unit is to be used with the enviroFlu sensor
Back to top
 

TriOS BUOY-150 custom built buoy system for environmental monitoring

Back to top