Cerlic ITX TSS sensor for MLSS
- A high accuracy, online, NIR (near infrared) total suspended solids (TSS) sensor for MLSS (mixed liquor suspended solids)
- Built-in self-cleaning (NOT clipped on) with water or compressed air - no moving parts for low maintenance
- NO service agreements
- Range: 0 » up to 20,000mg/L (ppm) or 2% TSS - dependent on sludge
- Process connection: handrail or slide rail mount
- Temperature: 0 » 60°C
- Enclosure: IP68 (submersible)
- Life expectancy: sensor 10yrs
- Accuracy: ±0.5% FS (TSS)
- Outputs: 4»20mA or optional Profibus DP from BB1 (single sensor - link) or BB2 (up to 4 sensors - link) controller
- Wetted Materials: 316SS & BK7 glass
- See the self-cleaning in action - YouTube demo
- See the telescopic rod with rail mounting kit in action - YouTube demo
Back to top |
ITX - suspended solids sensor datasheet (PDF)
Rail mounting kit (PDF)
DO & TSS sensors installed (JPG)
ITX self cleaning (JPG)
Cerlic - Sludge handling brochure (PDF)
|
 |
|
Cerlic ITX-IL in-line TSS sensor for RAS / WAS / DAF thickened sludge
- A high accuracy in-line NIR (near infrared) total suspended solids (TSS) sensor for RAS (return activated sludge) / WAS (waste activated sludge) & some DAF (dissolved air floatation) thickened sludge
- Built-in self-cleaning (NOT clipped on) with water or compressed air - no moving parts for low maintenance
- NO service agreements
- Range: 0 » up to 50,000mg/L (ppm) or 5% TSS - dependent on sludge
- Process connection: hot-tap via isolation valve prevents having to stop process in case of maintenance
- Temperature: 0 » 60°C
- Enclosure: IP65
- Life expectancy: sensor 10yrs
- Accuracy: ±1% FS (TSS)
- Outputs: 4»20mA or optional Profibus DP from BB1 (single sensor - link) or BB2 (up to 4 sensors - link) controller
- Wetted Materials: 316SS & BK7 glass
Back to top |
ITX-IL inline TSS sensor - datasheet (PDF)
ITX-IL installed (vertical pipe) (JPG)
ITX-IL installed (horizontal pipe with tapping band) (JPG)
Cerlic - Sludge handling brochure (PDF)
|
 |
|
Cerlic CMC high concentration TS sensor
- Micowave, high concentraion total solids (TS) sensor
- True-Phase shift microwave technology provides stable signal & prevents empty pipe errors
- No moving parts for long life & low maintenance
- Multiple models to suit various applications:
- CMC FT: flow through model with angled ceramic sensor (antenae) surfaces for self-cleaning
- CMC RD: flow through model with flush-mount ceramic sensor (antenae) surface for abbrassive applications. Various coatings available for additional protection.
- CMC ITL: **New** insertion type model with built-in spray cleaning (air or water) with no moving parts. Suitable for pipes >DN150. Also available as "hot-tap" (i.e. remove from pipe without stopping flow) model - CMC ITLFV.
- Designed for digested, dewatered, thickened or primary sluge
- Range: up to 30% TS (300,000mg/L or ppm)
- Process connection: wafer flange for DN50 » 300 or insertion type (CMC ITL) with optional hot-tap assembly
- Conductivity: varies depending on pipe size - refer datasheet
- Process pH: 2.5» 11.5
- Temperature: 0 » 100°C (process), 0 » 60°C (ambient)
- Pressure: PN16 (recommend at least 1.5bar to remove air from sludge / biosolids)
- Supply: choice of 85»264Vac or 24Vdc
- Display: remote mount with supplied 10m cable
- Enclosure: IP65
- Accuracy: ±1% FS (TSS)
- Outputs: 3 x 4-20mA analogue outputs or optional HART
- TS concentration (%, ppm, mg/L, g/L)
- Sludge temperature
- Programmable AUX: line pressure (pressure transducer models), conductivity, signal quality (diagnostics)
Back to top |
Cerlic - Sludge handling brochure (PDF)
CMC - datasheet (23_06, C104D1EN16b) (PDF)
Manual - CMC (C104E5EN21, CCPL) (PDF)
CMC-ITLFV Flush System & Hot-Tap Assembly - Datasheet (PDF)
|
 |
|
Cerlic O2X DUO dissolved oxygen sensor (optical or galvanic)
- Built-in self-cleaning (NOT mounted externally) with water or compressed air - no moving parts for low maintenance
- Range: 0 » 20mg/L
- Outputs: 4»20mA or optional Profibus DP from BB1 (single sensor - link) or BB2 (up to 4 sensors - link) controller
- Mounting: submersible sensor (IP68) mounted on 4m spring loaded telescopic rod (fibreglass), slide rail or chain
- Life expectency:
- Consumable sensing cells: 18»24 months (electrochemical), 2»3yrs luminophore (factory replacement) & 5»10yrs cell (complete optical cell)
- Sensor: 10yrs
- Temperature: 0»50°C
- Wetted materials: 316SS
- See the telescopic rod with rail mounting kit in action - YouTube demo
- See the self-cleaning in action - YouTube demo
Back to top |
O2X Duo - dissolved oxygen sensor (PDF)
The Cerlic Duo concept for dissolved oxygen (PDF)
O2XDUO - self cleaning (JPG)
Rail mounting kit (PDF)
DO & TSS sensors installed (JPG)
Cerlic - Wastewater systems brochure (PDF)
|
 |
|
Cerlic MultiTracker with MultiSeries sensors
- Handheld controller for MultiSeries plug and play sensors
- Parameters: sludge blanket profile (Blanko), total suspended solids (Solido) & dissolved oxygen (OxyDuo)
- Datalogging: 250 samples
- Display: backlit graphical LCD
- Alarms: vibration & audio at adjustable set points
- Keypad: push-button programming of all setttings
- Supply: 4 x AA (approx. 2»yrs operation, sensor dependent)
- Cables: 4, 8, 12 or 20m
- Enclosure: IP65
- See it in action - YouTube demo
- NEW! With the latest Firmware update of the MultiTracker (v2.3) the Solido can now store & use three separate calibration curves
- Operators can now datalog for three separate applications (e.g. MLSS, RAS & effluent) with the one device, without having to re-calibrate for each between uses!
- Software & drivers
- TrackerTalk 1.0
- USB-to-Serial converter (now available for up to Windows 10) - to download:
-
- scroll down to Support & Download tab
- then scroll down to Software & Drivers & under the heading of Windows Software & Driver click the link to download the most suitable (& up to date) .zip version of the driver for your computer
- extract the .zip file and follow the on-screen prompts to install the driver to your PC
- NOTE: please do this BEFORE plugged your MultiTracker datakit in for the first time to ensure the correct driver is loaded. Depending on your computer settings this may require Administrator access
- Latest Firmware Update (HEX2_3) - please strictly follow the TrackerTalk upgrade directions when updating the Firmware
Back to top |
Solido calibration curve.JPG (JPG)
TrackerTalk - screen print (JPG)
MultiTracker cable winder + TrackerTalk for PC Sync (JPG)
MultiTracker - portable control unit for MultiSeries sensors (complete) (PDF)
Manual - MultiTracker (C84F5EN19, CCPL) (PDF)
|
 |
|
Cerlic Blanko sludge blanket level (SBL) & profile sensor
- Combines a NIR (near infrared) suspended solids sensor with hydrostatic pressure transducer to accurately plot TSS vs depth for complete sludge blanket profile
- Plug and play connection to the MultiTracker handheld controller
- Range: 0 » up to 20,000mg/L (ppm) or 2% TSS - dependent on sludge
- Depth: up to 19m
- Temperature: 0 » 50°C
- Enclosure: IP68 (handheld MultiTracker IP65)
- Accuracy: ±1% FS (TSS), ±0.5% FS (depth)
- Output: profile via graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (fluff & sludge blanket)
- Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
- Wetted Materials: 316SS, BK7 glass & PUR (cable)
- See it in action - YouTube demo
Back to top |
Blanko - MultiSeries sludge blanket sensor (PDF)
Full sludge blanket profile explained (JPG)
TrackerTalk - screen print (JPG)
Sludge Blanket Measurement - CBX & portable Blanko (PDF)
MultiTracker - portable control unit for MultiSeries sensors (complete) (PDF)
Sludge blanket profile sensors (JPG)
|
 |
|
Cerlic Solido TSS sensor for RAS / WAS / MLSS
- A high accuracy NIR (near infrared) total suspended solids (TSS) sensor for RAS (return activated sludge) / WAS (waste activated sludge) / MLSS (mixed liquor suspended solids)
- Plug and play connection to the MultiTracker handheld controller
- Range: 0 » up to 50,000mg/L (ppm) or 5% TSS - dependent on sludge
- Depth: up to 12m
- Temperature: 0 » 50°C
- Enclosure: IP68 (handheld MultiTracker IP65)
- Accuracy: ±1% FS (TSS)
- Output: graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (high & low)
- Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
- Wetted Materials: 316SS, BK7 glass & PUR (cable)
- NEW! With the latest Firmware update of the MultiTracker (v2.3) the Solido can now store & use three separate calibration curves
- Operators can now datalog for three separate applications (e.g. MLSS, RAS & effluent) with the one device, without having to re-calibrate for each between uses!
- Head to the MultiTracker page (here) to download the updates
Back to top |
Solido MultiTracker Sensor - datasheet (PDF)
TrackerTalk - screen print (JPG)
Solido calibration curve.JPG (JPG)
MultiTracker - portable control unit for MultiSeries sensors (complete) (PDF)
|
 |
|
Cerlic OxyDuo dissolved oxygen (DO) sensor
- Dissolved oxygen (DO) sensor with your choice of optical or electrochemical (Clarke) cell
- Plug and play connection to the MultiTracker handheld controller
- Only ever replace the consummable sensing cell
- Range: 0 » up to 20mg/L (ppm)
- Depth: up to 12m
- Temperature: 0 » 50°C
- Enclosure: IP68 (handheld MultiTracker IP65)
- Accuracy: Electrochemical: ±1% FS, Optical: ±0.1mg/L <5mg/L, ±0.2mg/L > 5mg/L
- Output: graphical (backlit) display, alarms (vibration & sound) for 2 x adjustable levels (high & low)
- Datalog up to 250 samples into customised folders before PC sync via supplied cable & software
- Wetted Materials: sensor cell components, 316SS body & PUR (cable)
Back to top |
OxyDuo - MultiSeries dissolved oxygen sensor (PDF)
The Cerlic Duo concept for dissolved oxygen (PDF)
TrackerTalk - screen print (JPG)
MultiTracker - portable control unit for MultiSeries sensors (complete) (PDF)
|
 |
|
Cerlic CBX & CBX+ sludge blanket level (SBL) & profile sensor
- Combines NIR suspended solids sensor with accurate depth measurement to provide sludge blanket profile
- Analogue outputs for: sludge blanket level, fluff (unsettled sludge) level, real-time TSS concentration & real-time sensor depth
- 4-20mA or Profibus DP output (optional)
- Completely self-cleaning
- Two models:
- CBX: range up to 2% TSS (depending on sludge type)
- CBX+: range up to 5% TSS (depending on sludge type)
- See it in action - YouTube demo
Back to top |
CBX - datasheet (PDF)
CBX - sludge blanket measurement animation (SWF)
Manual - CBX (CCPL) (PDF)
Sludge Blanket Measurement - CBX & portable Blanko (PDF)
Sludge blanket profile sensors (JPG)
|
 |
|
Cerlic BB2 centralised control box for X-series sensors
- Controls up to 4 sensors at once, including self-cleaning solenoids
- Outputs: 2 x 4-20mA (standard) expandable up to 4 x 4-20mA for 4 online sensors
- Use for analytical variables (TSS / DO etc) or temperature
- 2 x independent relays
- Profibus output optional
- Supply: choice of 85-250VAC or 12-30VDC
- Temperature: -20 » 55°C (ambient) with built-in automatic heater
- Enclosure: IP65 / NEMA4X
- Materials: polycarbonate
- Stocked models: 11905426 and 11906087
Back to top |
Manual - BB2 central control unit (including 24Vdc) (PDF)
BB2 - sensor controller & transmitter (PDF)
|
 |
|
Cerlic MultiFix controller for MultiSeries sensors
- Fixed controller for MultiSeries plug and play sensors
- Parameters: total suspended solids (Solido - link) & dissolved oxygen (OxyDuo - link)
- Outputs:
- Display: backlit graphical LCD
- Alarms: vibration & audio at adjustable set points
- Keypad: push-button programming of all setttings
- Supply: choice of 12-36VDC, 110/240VAC or universal AC/DC model
- Sensor Cables: 8m (standard) - OEM versions possible
- Enclosure: IP54 / NEMA3
- Temperature: -10 » 50°C
- Stocked Model: 11906024 (DC)
Back to top |
MultiFix - datasheet (PDF)
Solido - MultiSeries suspended solids sensor (PDF)
OxyDuo - MultiSeries dissolved oxygen sensor (PDF)
Manual - MultiFix (PDF)
|
 |
|
Cerlic BB1 central control box for X-series sensors **now discontinued - replace with BB2 240VAC (p/n: 11905426) - link**
- Controls just one sensor
- Outputs: all outputs from one sensor
- 2 x 4-20mA as a standard, but expandable up to 4 x 4-20mA for CBX with full range of outputs (sludge blanket level, fluff level, real-time depth & concentration)
- Use for analytical variables (TSS / DO etc) or temperature
- Profibus output optional
- Supply: 85 - 230VAC
Back to top |
BB1 - control box for Cerlic sensors (PDF)
Manual - BB1 (CCPL) (PDF)
|
 |
|
Cerlic pHx (pH) & ReX (ORP or redox) sensors Back to top |
pHX + ReX - pH & ORP sensors (PDF)
ORP electrode (PDF)
pH electrode (PDF)
Manual - pHX (pH) + ReX (redox) sensors (PDF)
|