Pressure Switches from 2kPa to 500bar
  • Field adjustable or factory set
  • Compact OEM versions to heavy duty Industrial types
  • Always dependable
  • Enclosures include aluminium, stainless steel, baked on enamel
  • Minimum NEMA 4 ( ~ IP65 )
  • Pressure Switches Selection Guide (78Kb pdf)

  • Pressure Switches Instruction Bulletin (25Kb pdf)

  • OEM Subminiature Pressure Switches
  • Field adjustable or factory set
  • PS-JL Low Pressure 0.15 10 bar ( 2-150 PSI )
  • PS-J High Pressure 0.35 210 bar ( 5-3000 PSI )
  • 1/4 or 1/8 BSPP or NPT male
  • SPST NO or NC 100VA, 42V max
  • Deadband 7 14kPa ( 1-2 PSI )
  • PS-J, JL Specs (95Kb pdf)

  • Pressure Switches Instruction Bulletin (25Kb pdf)

  • Miniature Pressure Switches
  • Field adjustable or factory set
  • PS-E Low Pressure 0.2 7 bar ( 2-150 PSI )
  • PSEV Vacuum 150 925 mbar ( 5 28 Hg )
  • PS-EH High Pressure 0.7 210 bar ( 10 3000 PSI )
  • 1/4 BSPP or NPT , 7/16 UNF-20 male
  • SPDT 5 Amp 240VAC & 12/24VDC microswitch
  • Deadbands fixed per range
  • PS-E, EV, EH Specs (88Kb pdf)

  • Pressure Switches Instruction Bulletin (25Kb pdf)

  • Differential Pressure Switches
  • Field adjustable or factory set
  • PS-D Ranges : 0.7-1.7 bar, 1.3 3.0 bar
  • Deadbands 50% of max
  • IP65 enclosure
  • 1/4 BSPP or NPT male
  • SPDT 5 Amp 240VAC & 12/24VDC microswitch
  • Deadbands fixed per range
  • PS-D Specs (81Kb pdf)

  • Pressure Switches Instruction Bulletin (25Kb pdf)

  • Mid Range Pressure Switches
  • Field adjustable or factory set
  • PS-FA, FB ranges 0.35 420 bar ( 5-6000 PSI )
  • Up to 600 bar proof pressure
  • 1/4 BSPP or NPT male & female fittings
  • SPDT/DPDT 5 Amp 240VAC & 12/24VDC microswitch
  • IP65 Enclosure side or top entry
  • PS-FA, FB Specs (80Kb pdf)

  • Pressure Switches Instruction Bulletin (25Kb pdf)

  • Industrial Pressure Switches
  • Field adjustable or factory set
  • PS-K ranges 0.35 420 bar ( 5-6000 PSI )
  • Adjustable deadband
  • Up to 600 bar proof pressure
  • 1/4 BSPP or NPT male & female fittings
  • SPDT/DPDT 20 Amp 240VAC & 12/24VDC microswitch
  • IP65 Enclosure
  • PS-K Specs (71Kb pdf)

  • Pressure Switches Instruction Bulletin (25Kb pdf)

  • Pressure Transmitters & Transducers
  • Excellent Repeatability & Reliability
  • Pressure ranges Vacuum to 690 bar
  • Chemical Vapour Deposition technology for accuracy
  • Modular design reduces costs and delivery times
  • OEM types, high temperature and specialty designs
  • Pressure Transducers (236Kb pdf) Technology

  • Transmitters Technology (80Kb pdf)

  • Gems CVD Psibar brochure (507Kb pdf)

  • Pressure Transducers 2200/2600 Series
  • Vacuum to 414 bar ( 6000 psig )
  • Accuracy 0.25% ( 0.15% optional )
  • Long Term Drift ( Full Scale/year ) 0.20%
  • Thermal Error ( Full scale typical ) 0.015%
  • Operating Temperatures 40°C to 125°C
  • Sensor Technology Strain Gauge CVD type
  • Proof Pressure 2 X Full scale ( 1.5X for 400 bar )
  • 2200, 2600 Specs (346Kb pdf)

  • Gems CVD Psibar brochure (507Kb pdf)

  • Pressure Transducers High Proof Pressure 1200/1600 Series
  • Vacuum to 414 bar ( 6000 psig ) gauge datum only
  • Accuracy 0.25% ( 0.15% optional )
  • Long Term Drift ( Full Scale/year ) 0.20%
  • Thermal Error ( Full scale typical ) 0.015%
  • Operating Temperatures 40°C to 125°C
  • Sensor Technology Strain Gauge CVD type
  • Proof Pressure 4 X Full scale ( 1.5X for 400 bar )
  • 1200, 1600 Specs (222Kb pdf)

  • Gems CVD Psibar brochure (507Kb pdf)

  • Pressure Transducers Compact High Pressure OEM 1000 Series
  • 16 to 2200 bar ( 250 to 30,000 psig )
  • Accuracy 0.25% ( 0.15% optional )
  • Long Term Drift ( Full Scale/year ) 0.10%
  • Thermal Error ( Full scale typical ) 2%
  • Operating Temperatures 40°C to 120°C
  • Sensor Technology Strain Gauge Sputtered Thin Film
  • 1000 Specs (2017Kb pdf)

  • Pressure Transducers High Performance, Long Term Stability 4000K Series
  • 0 to 690 bar ( 15 to 10,000 psi )
  • Accuracy 0.08% of span ( min )
  • Long Term Drift 0.06% per year, non cumulative
  • Thermal Error 0.03% ( min ) to 1.2% ( max )
  • Operating Temperatures 54°C to 135°C ( max range )
  • Sensor Technology Strain Gauge Sputtered Thin Film type
  • 4000K Specs (235Kb pdf)

  • Pressure Transducers High Temperature, High Performance, Long Term Stability 4000L Series
  • 0 to 690 bar ( 15 to 10,000 psi )
  • Accuracy 0.1% Full Scale typical
  • Long Term Drift 0.06% per year, non cumulative
  • Thermal Error 0.01% FS/C
  • Operating Temperatures 54°C to 230°C ( max range )
  • Sensor Technology Strain Gauge Sputtered Thin Film type
  • 4000L Specs (197Kb pdf)

  • Pressure Transducers Industrial Duty Differential GBD Series
  • 40mbar to 6 bar ( 0.6 to 87 psi )
  • Accuracy 0.2% of max span typical
  • Thermal Error 1.5% of max span typical
  • Operating Temperatures 20°C to 100°C
  • Sensor Technology LVDT type
  • Proof Pressure 35 bar for 40 mbar range, 50 bar for 160 mbar range, 100 bar for all others
  • GBD Specs (271Kb pdf)

  • Pressure Transducers Sanitary 3-A 890 Series
  • 69 mbar to 69 bar ( 1 to 1000 psig )
  • Accuracy 0.2% FS
  • Thermal Error 0.036% FS/0C
  • Operating Temperatures 40°C to 125°C
  • Sensor Technology : Capacitance
  • Output 4-20mA ( 2 wire )
  • Proof Pressure refer Specs
  • 890 Specs (691Kb pdf)

  • 890 Instructions (83Kb pdf)

  • Pressure Transducers Immersible Types
  • Immersible to 200 metres ( 650 )
  • Millivolt and Current outputs
  • All welded stainless steel construction
  • Hastelloy C or Inconel for seawater applications
  • Factory Set or Customer adjustable ranges
  • Various sensor technologies
  • 2400 Slimline Specs (48Kb pdf)

  • 2600 Immersible Specs (337Kb pdf)

  • 4000K Immersible High Performance Specs (235Kb pdf)

  • 4000L Immersible High Performance Specs (197Kb pdf)

  • 4700 High Stability Specs (106Kb pdf)

  • 5000 Low Pressure Specs (142Kb pdf)

  • 6600 Immersible Specs (342Kb pdf)

  • GCL Submersible Specs (237Kb pdf)

  • Pressure Transducers Wet/Wet Differential 830 Series
  • 69 mbar to 6.9 bar ( 1 to 100 psid )
  • Accuracy 0.25% of full scale
  • Thermal Error 0.036% FS/0C
  • Operating Temperatures 18°C to 80°C
  • Sensor Technology : Capacitance
  • Proof Pressure : refer Specs
  • Outputs : 0-5 or 0-10VDC, 4-20mA (2 wire )
  • 830 Setra Specs (1024Kb pdf)

  • 830 Setra Instructions (85Kb pdf)

  • Pressure Transducers Low Differential 865 Series
  • Air and non conductive gases
  • Ranges between 0 and 100 inches WC
  • Accuracy +/-1% FS ( standard ), options ; 0.4% & 0.25%
  • Thermal Error +/-0.06% FS/0C
  • Operating Temperatures 18°C to 65°C
  • Sensor Technology : Capacitance
  • Proof Pressure : 700 mbar
  • 865 Setra Specs (693Kb pdf)

  • 865 Setra Instructions (65Kb pdf)