Pressure Switches from 2kPa to 500bar
Field adjustable or factory set
Compact OEM versions to heavy duty Industrial types
Always dependable
Enclosures include aluminium, stainless steel, baked on enamel
Minimum NEMA 4 ( ~ IP65 )
|
Pressure Switches Selection Guide (78Kb pdf)
Pressure Switches Instruction Bulletin (25Kb pdf)
|
 |
 |
 |
OEM Subminiature Pressure Switches
Field adjustable or factory set
PS-JL Low Pressure 0.15 – 10 bar ( 2-150 PSI )
PS-J High Pressure 0.35 – 210 bar ( 5-3000 PSI )
1/4” or 1/8” BSPP or NPT male
SPST NO or NC 100VA, 42V max
Deadband 7 – 14kPa ( 1-2 PSI )
|
PS-J, JL Specs (95Kb pdf)
Pressure Switches Instruction Bulletin (25Kb pdf)
|
 |
 |
 |
Miniature Pressure Switches
Field adjustable or factory set
PS-E Low Pressure 0.2 – 7 bar ( 2-150 PSI )
PSEV Vacuum 150 – 925 mbar ( 5 – 28” Hg )
PS-EH High Pressure 0.7 – 210 bar ( 10 3000 PSI )
1/4” BSPP or NPT , 7/16” UNF-20 male
SPDT 5 Amp 240VAC & 12/24VDC microswitch
Deadbands fixed per range
|
PS-E, EV, EH Specs (88Kb pdf)
Pressure Switches Instruction Bulletin (25Kb pdf)
|
 |
 |
 |
Differential Pressure Switches
Field adjustable or factory set
PS-D Ranges : 0.7-1.7 bar, 1.3 – 3.0 bar
Deadbands 50% of max
IP65 enclosure
1/4” BSPP or NPT male
SPDT 5 Amp 240VAC & 12/24VDC microswitch
Deadbands fixed per range
|
PS-D Specs (81Kb pdf)
Pressure Switches Instruction Bulletin (25Kb pdf)
|
 |
 |
 |
Mid Range Pressure Switches
Field adjustable or factory set
PS-FA, FB ranges 0.35 – 420 bar ( 5-6000 PSI )
Up to 600 bar proof pressure
1/4” BSPP or NPT male & female fittings
SPDT/DPDT 5 Amp 240VAC & 12/24VDC microswitch
IP65 Enclosure side or top entry
|
PS-FA, FB Specs (80Kb pdf)
Pressure Switches Instruction Bulletin (25Kb pdf)
|
 |
 |
 |
Industrial Pressure Switches
Field adjustable or factory set
PS-K ranges 0.35 – 420 bar ( 5-6000 PSI )
Adjustable deadband
Up to 600 bar proof pressure
1/4” BSPP or NPT male & female fittings
SPDT/DPDT 20 Amp 240VAC & 12/24VDC microswitch
IP65 Enclosure
|
PS-K Specs (71Kb pdf)
Pressure Switches Instruction Bulletin (25Kb pdf)
|
 |
 |
 |
Pressure Transmitters & Transducers
Excellent Repeatability & Reliability
Pressure ranges Vacuum to 690 bar
Chemical Vapour Deposition technology for accuracy
Modular design reduces costs and delivery times
OEM types, high temperature and specialty designs
|
Pressure Transducers (236Kb pdf)
Technology
Transmitters Technology (80Kb pdf)
Gems CVD Psibar brochure (507Kb pdf)
|
 |
 |
 |
Pressure Transducers – 2200/2600 Series
Vacuum to 414 bar ( 6000 psig )
Accuracy 0.25% ( 0.15% optional )
Long Term Drift ( Full Scale/year ) 0.20%
Thermal Error ( Full scale typical ) 0.015%
Operating Temperatures –40°C to 125°C
Sensor Technology Strain Gauge CVD type
Proof Pressure 2 X Full scale ( 1.5X for 400 bar )
|
2200, 2600 Specs (346Kb pdf)
Gems CVD Psibar brochure (507Kb pdf)
|
 |
 |
 |
Pressure Transducers – High Proof Pressure 1200/1600 Series
Vacuum to 414 bar ( 6000 psig ) gauge datum only
Accuracy 0.25% ( 0.15% optional )
Long Term Drift ( Full Scale/year ) 0.20%
Thermal Error ( Full scale typical ) 0.015%
Operating Temperatures –40°C to 125°C
Sensor Technology Strain Gauge CVD type
Proof Pressure 4 X Full scale ( 1.5X for 400 bar )
|
1200, 1600 Specs (222Kb pdf)
Gems CVD Psibar brochure (507Kb pdf)
|
 |
 |
 |
Pressure Transducers – Compact High Pressure OEM 1000 Series
16 to 2200 bar ( 250 to 30,000 psig )
Accuracy 0.25% ( 0.15% optional )
Long Term Drift ( Full Scale/year ) 0.10%
Thermal Error ( Full scale typical ) 2%
Operating Temperatures –40°C to 120°C
Sensor Technology Strain Gauge Sputtered Thin Film
|
1000 Specs (2017Kb pdf)
|
 |
 |
 |
Pressure Transducers – High Performance, Long Term Stability 4000K Series
0 to 690 bar ( 15 to 10,000 psi )
Accuracy 0.08% of span ( min )
Long Term Drift 0.06% per year, non cumulative
Thermal Error 0.03% ( min ) to 1.2% ( max )
Operating Temperatures –54°C to 135°C ( max range )
Sensor Technology Strain Gauge Sputtered Thin Film type
|
4000K Specs (235Kb pdf)
|
 |
 |
 |
Pressure Transducers – High Temperature, High Performance, Long Term Stability 4000L Series
0 to 690 bar ( 15 to 10,000 psi )
Accuracy 0.1% Full Scale typical
Long Term Drift 0.06% per year, non cumulative
Thermal Error 0.01% FS/C
Operating Temperatures –54°C to 230°C ( max range )
Sensor Technology Strain Gauge Sputtered Thin Film type
|
4000L Specs (197Kb pdf)
|
 |
 |
 |
Pressure Transducers – Industrial Duty Differential GBD Series
40mbar to 6 bar ( 0.6 to 87 psi )
Accuracy 0.2% of max span typical
Thermal Error 1.5% of max span typical
Operating Temperatures –20°C to 100°C
Sensor Technology LVDT type
Proof Pressure 35 bar for 40 mbar range, 50 bar for 160 mbar range, 100 bar for all others
|
GBD Specs (271Kb pdf)
|
 |
 |
 |
Pressure Transducers – Sanitary 3-A 890 Series
69 mbar to 69 bar ( 1 to 1000 psig )
Accuracy 0.2% FS
Thermal Error 0.036% FS/0C
Operating Temperatures –40°C to 125°C
Sensor Technology : Capacitance
Output 4-20mA ( 2 wire )
Proof Pressure refer Specs
|
890 Specs (691Kb pdf)
890 Instructions (83Kb pdf)
|
 |
 |
 |
Pressure Transducers – Immersible Types
Immersible to 200 metres ( 650’ )
Millivolt and Current outputs
All welded stainless steel construction
Hastelloy C or Inconel for seawater applications
Factory Set or Customer adjustable ranges
Various sensor technologies
|
2400 Slimline Specs (48Kb pdf)
2600 Immersible Specs (337Kb pdf)
4000K Immersible High Performance Specs (235Kb pdf)
4000L Immersible High Performance Specs (197Kb pdf)
4700 High Stability Specs (106Kb pdf)
5000 Low Pressure Specs (142Kb pdf)
6600 Immersible Specs (342Kb pdf)
GCL Submersible Specs (237Kb pdf)
|
 |
 |
 |
Pressure Transducers – Wet/Wet Differential 830 Series
69 mbar to 6.9 bar ( 1 to 100 psid )
Accuracy 0.25% of full scale
Thermal Error 0.036% FS/0C
Operating Temperatures –18°C to 80°C
Sensor Technology : Capacitance
Proof Pressure : refer Specs
Outputs : 0-5 or 0-10VDC, 4-20mA (2 wire )
|
830 Setra Specs (1024Kb pdf)
830 Setra Instructions (85Kb pdf)
|
 |
 |
 |
Pressure Transducers – Low Differential 865 Series
Air and non conductive gases
Ranges between 0 and 100 inches WC
Accuracy +/-1% FS ( standard ), options ; 0.4% & 0.25%
Thermal Error +/-0.06% FS/0C
Operating Temperatures –18°C to 65°C
Sensor Technology : Capacitance
Proof Pressure : 700 mbar
|
865 Setra Specs (693Kb pdf)
865 Setra Instructions (65Kb pdf)
|
 |